Daniel Manu、Prathap Basappa2020-06-01OpenAlex
This paper entails the design and development of a Partial Discharge processing and analysis system (PDPAS) for the acquisition and analysis of partial discharges (PD) which can measure the phase ‘$\Phi^{\prime}$, charge magnitude ‘q’ and number of pulses ‘n’ occurring in a given AC power line cycle and plot them in a…
High voltage insulation and dielectric phenomenaLightning and Electromagnetic PhenomenaPower Transformer Diagnostics and Insulation
Andrea Delfini、Roberto Pastore、Fabio Santoni 等 5 位作者2020-06-01OpenAlex
A critical aspect to be addressed through materials engineered for aerospace missions is to provide the protection of space subsystems from the aggressive operative environment, in order to extend the life of such subsystem. Taking this fact into account, carbon-based ceramic composites are ideal candidates for the ne…
Ionosphere and magnetosphere dynamicsGas Dynamics and Kinetic TheorySilicone and Siloxane Chemistry
Joseph Potvin、J. G. Tripolitis、J.H. Groeger2020-06-01OpenAlex
An electric utility company discovered delaminating underground low voltage secondary network cable insulation in service, in addition to damaged cables with exposed conductors. A condition assessment study was undertaken to characterize the insulation materials to provide insight into the observed cable condition and…
High voltage insulation and dielectric phenomenaLightning and Electromagnetic PhenomenaElectrical Fault Detection and Protection
Charles Nybeck、Volney Naranjo2020-06-01OpenAlex
It is imperative that transformers in distribution and transmission substations function properly in order to avoid any damage or unnecessary system outages. There are diagnostic tests recommended in various international standards that can provide early evidence of possible issues within the equipment's overall healt…
High voltage insulation and dielectric phenomenaLightning and Electromagnetic PhenomenaPower Transformer Diagnostics and Insulation
M.G. Krieg-Wezelenburg2020-06-01OpenAlex
Dielectric Dissipation Factor (DDF) measurements are used to assess the manufacturing quality of individual stator bars/coils and the dielectric behavior of the electrical insulation system of stator windings. The use of this diagnostic test method is widespread and standardized in IEEE and IEC documents. The new IEC…
High voltage insulation and dielectric phenomenaLightning and Electromagnetic PhenomenaPower Transformer Diagnostics and Insulation
С. В. Борисов、Н. В. Первухина、С. А. Магарилл2020-06-01Journal of Structural Chemistry
For the cubic structures of analcime Na 1.71 (Al 1.8 ,Si 4.2 )O 12 ·2H 2 O, pollucite CsAlSi 2 O 6 and tetragonal (but pseudo-cubic) kirchhoffite CsBSi 2 O 6 and leucite KAlSi 2 O 6 the common stencil (pattern) of cation arrangement at the key positions of symmetry space groups related with configurations in spinel, d…
High-pressure geophysics and materialsGlass properties and applicationsCrystal Structures and Properties
Y. M. Chen、Xiao-Yi Xiong、Liang-Yu Huang 等 6 位作者2020-06-01Journal of Structural Chemistry
A new 1D Cd(II) complex [Cd(L-pheA)(Ac)] n (1) where the L-pheA − anion stands for the chiral ligand (L-phenylalanine hydroxamic acid) is synthesized and characterized. The single crystal X-ray analysis reveals that each Cd(II) atom is coordinated by three L-pheA − ligands and two acetate anions in a distorted seven-c…
Metal-Organic Frameworks: Synthesis and ApplicationsMetal complexes synthesis and propertiesMagnetism in coordination complexes
Sadegh Ghanbar、Sedigheh Nazaripour、Marek Kornowski 等 4 位作者2020-06-01OpenAlex
Epoxy resin samples were prepared using cycloaliphatic resin and anhydride curing agents. Response Surface Methodology (RSM) was applied to determine the effect of five independent variables (Silbond W12EST, MoldXA400, CSR, PC1000 and BYK3701) at 5 levels on the dependent variables thermal shock crack resistance (TSR)…
Advanced Sensor and Energy Harvesting MaterialsHigh voltage insulation and dielectric phenomenaElectrical Fault Detection and Protection
Kaige Yang、Ming Dong、Yizhuo Hu 等 5 位作者2020-06-01OpenAlex
Frequency Domain Spectrum analysis method (FDS), for its lots of advantages, has been widely concerned and applied in state characterization of insulating materials and insulation diagnosis of power equipment. However, in the current research, the characteristic parameters of FDS are not reliable and accurate enough i…
High voltage insulation and dielectric phenomenaPower Transformer Diagnostics and InsulationHigh-Voltage Power Transmission Systems
W. McDermid、Mike Partyka、T. Black2020-06-01OpenAlex
The PAR for IEEE P2465 was issued in 2017. Draft 9 of the document dated September 2019 contains sections on Measurement Circuits (both low frequency and HF/VHF), the Simulated Slot including measurement of clamping pressure, Method for calibration or normalization, Test voltages and protection, Conditioning and test…
High voltage insulation and dielectric phenomenaAnalytical Chemistry and SensorsSensor Technology and Measurement Systems
A. Mavinkurve、K. Kasuriya、R.T.H. Rongen 等 7 位作者2020-06-01OpenAlex
Several papers have described the corrosion mechanisms induced by HAST at 110 or 130°C in copper wire packages. Most of them refer to intrinsic behavior (e.g. the ionic contamination level of the materials, wirebond quality), but there is limited work published on mechanisms induced as a result of extrinsic causes. On…
Electronic Packaging and Soldering TechnologiesSemiconductor materials and devicesCopper Interconnects and Reliability
Xiaolong Xu、Hangwei Zhang、Fenglian Liu 等 6 位作者2020-06-01OpenAlex
The dielectric loss is one of the vital indicators for the insulation status of power cables. However, the current dielectric loss measurement methods which have insufficient accuracy cannot meet field test requirements. In order to solve the shortcomings of the current method, this paper proposes a dielectric loss me…
Advanced Fiber Optic SensorsHigh voltage insulation and dielectric phenomenaElectrical Fault Detection and Protection
Wei-You Hsu、Yujin Li、I-Hsin Tseng 等 6 位作者2020-06-01OpenAlex
This study investigates the toughness of 40-μm-wide nanotwinned Cu lines before and after annealing. The toughness of Cu lines was measured by tensile test, and different annealing temperatures and durations were used to examine the thermal stability of the nt-Cu films. The initial and post-annealed microstructures wa…
Electronic Packaging and Soldering Technologies3D IC and TSV technologiesCopper Interconnects and Reliability
A Mousapour Gorji、Sarajit Banerjee、Shesha Jayaram2020-06-01OpenAlex
In this work, a systematic study of the dielectric spectra of full-scale medium-voltage (MV) ethylene propylene rubber- (EPR) and tree-retardant cross-linked polyethylene-(TR-XLPE) insulated cables is presented within the frequency range from 10-1Hz to 106Hz at various temperatures from 25 °C to 80 °C. The measured sp…
Polymer Nanocomposites and PropertiesHigh voltage insulation and dielectric phenomenaElectromagnetic wave absorption materials
Tyler R. Gaerke、Nicholas P. Lang2020-06-01OpenAlex
Surge testing of stator windings has long been used as part of incoming testing for inspections and documentation for machines with periodic maintenance plans. While IEEE 522 and IEC 60034-15 offer some guidance for performing the test on windings and windings which have been aged, neither offers acceptable results wh…
High voltage insulation and dielectric phenomenaNon-Destructive Testing TechniquesElectrical Fault Detection and Protection
Takahiro Umemoto、Takahiro Nakamura、Kazunari Karasawa2020-06-01OpenAlex
SiC-based nonlinear conductive stress grading tape (SGT) has been used at an end-turn stress grading system of a form-wound rotating machine. Although previous researches reported that high-frequency repetitive pulses cause electric field enhancement and local heating at the SG system, few paper deals with the detaile…
Silicon Carbide Semiconductor TechnologiesAdvanced Surface Polishing TechniquesMetal Alloys Wear and Properties
Wenxiang Xue、Yi Lu、Yanfeng Gao 等 7 位作者2020-06-01OpenAlex
The diagnosis of XLPE cable lines by partial discharge (PD) has always been a key technical issue. As an important parameter reflecting the insulation status of XLPE cable equipment, partial discharge is closely related to its insulation status. A state evaluation method of cable based on the growth of electrical tree…
High voltage insulation and dielectric phenomenaElectrical Fault Detection and ProtectionThermal Analysis in Power Transmission
Mangalsing Chavan、Faizan Alam、Pravin Gorde2020-06-01Journal of Emerging Technologies and Innovative Research
The recent developments in the application of the advanced composites in the construction industry for concrete rehabilitation and strengthening are increasing on the basis of specific requirements. A numerical analysis has been carried out to investigate the performance of reinforced concrete beam structure with natu…
Natural Fiber Reinforced CompositesSoil Mechanics and Vehicle Dynamics
Biraj Shougaijam、Salam Surjit Singh2020-06-012020 International Conference for Emerging Technology (INCET)
With the increase in demand of economic, ecofriendly, and portable solar cell, Dye-Sensitized Solar Cells (DSSCs) is a promising candidate which may give the above demands. The main objective of this research work is to adopt Glancing Angle Deposition (GLAD) technique for developing novel Gold (Au) nanoparticles assis…
TiO2 Photocatalysis and Solar CellsAdvanced Photocatalysis TechniquesQuantum Dots Synthesis And Properties
Tritod Nganpitak、Nattachote Rugthaicharoencheep、Phop Chancharoensook 等 4 位作者2020-06-01OpenAlex
Very low frequency tan delta measurement (VLF-TD measurement) is one of the insulation diagnosis methods usually uses to diagnosis the condition of electrical cable insulation. However, this research focuses on using VLF-TD measurement with a gas-insulated transmission line (GIL). The 230kV, 2500A, single phase, GIL w…
High voltage insulation and dielectric phenomenaPower Transformer Diagnostics and InsulationThermal Analysis in Power Transmission